Skip to main content
Probe Stabilization Settings
Curtis Nash avatar
Written by Curtis Nash
Updated over a week ago

Probe Stabilization Settings

Overview:

Customize the probe stabilization settings on your Jolt app to meet your specific food safety needs. Adjust these settings to ensure accurate temperature readings and recordings.

Prerequisites

  • Permissions: You must have Device Admin permissions to customize these settings.

Instructions

  1. Log In:

    • Open the Jolt app and ensure you are logged in as a Device Admin.

  2. Access Settings:

    • Navigate to Tools > Temperature.

    • Select the gear icon on the top right of the app to access the probe settings.

      Screenshot_20240313-092502_Jolt.jpg

Probe Settings

  1. Auto Record: Specific Range(s)

    • Description: Automatically records temperatures when they match the specific range(s) set for the item.

    • Setup: Configure the range on the item within the List Template on the Jolt Web Portal. For more details, refer to the Measurement List Item Type article.

  2. Auto Record: Food Safety Range

    • Description: Records temperatures automatically when below 50º F (refrigerated) or above 130º F (cooked).

    • Note: Adjust this range by setting specific ranges in the Auto Record: Specific Range(s) setting. A range must be added to the measurement item on the List Template.

  3. Require Temperature Stabilization

    • Description: Requires the probe to stabilize before recording. The probe takes multiple readings and will only be ready when the readings are within the accuracy rating and match the sensitivity setting.

    • Example: The probe will be ready after five consecutive readings with a variance of less than 0.5°.

    • Note: This setting is necessary for Auto Record.

  4. Require Temperature Change

    • Description: Ensures that the probe registers a temperature change between items. After recording an item, the probe must show a sufficient temperature change before recording the next item.

    • Example: If the probe is removed and the air temperature changes, the probe should be cleaned before measuring the next item.

    • Note: This setting is necessary for Auto Record.

  5. Beep When Temperature Recorded

    • Description: Emits a sound to alert the employee to move to the next item once a temperature is recorded.

      Screenshot_20240313-092507_Jolt.jpg
  6. Summary Screen Duration

    • Description: Sets how long the summary screen displays after recording a temperature.

    • Note: Adjust the color of the summary screen (Blue, Red, or Green) on the List Template within the Jolt Web Portal. This color helps visually indicate whether temperatures are within or outside the target range.

      Screenshot_20240313-092512_Jolt.jpg
      Screenshot_20240313-101037_Jolt.jpg

  7. Probe Calibration

    • Description: Adjusts the stabilization time and temperature accuracy for the Require Temperature Stabilization setting. Also allows adjustment of the temperature change required for the Require Temperature Change setting.

    • Note: Jolt offers Bluetooth probes with a Thick tip (DuraNeedle) and other attachments (Thin tip - MicroNeedle) available through Jolt supplies or third-party vendors.

      Screenshot_20240313-092518_Jolt.jpg

FAQs

Q: How do I know if I have Device Admin permissions?

A: Check your user profile or contact your company’s Jolt administrator to confirm your permissions.

Q: What should I do if the probe readings are not stabilizing?

A: Ensure that the Require Temperature Stabilization setting is correctly configured. If issues persist, check if the probe is properly calibrated or needs maintenance.

Q: How can I adjust the Auto Record ranges?

A: Adjust the ranges in the Jolt Web Portal under the List Template settings. For detailed instructions, refer to the Measurement List Item Type article.

Q: Why is it important to clean the probe between measurements?

A: Cleaning the probe ensures accurate temperature readings and prevents cross-contamination between items.

Q: What if I need a different type of probe?

A: Jolt offers different probes and attachments. Visit the Jolt supplies page or consult with third-party vendors for additional options.

Q: How do I adjust the Summary Screen color?

A: The color can be adjusted in the List Template settings on the Jolt Web Portal. Choose from Blue, Red, or Green to match your visual preferences.

Q: Can I use the probe with different temperature ranges?

A: Yes, you can configure the probe to record within specific temperature ranges by setting these ranges in the app or on the Jolt Web Portal.

Did this answer your question?